CDH
The CDH belong to our range of ALPHA ALUMINIUM HOUSED COMPACT BRAKE RESISTORS.
The CDH resistors are insulated and constructed in small dimensions so that they fit into compact constructions.
The resistor elements are wirewound helix elements mounted in and supported by a ceramic insulator.
The flat construction of CDH makes it ideal for heat sink cooled equipment.
The CDH resistors are available in two different protection degrees; IP50 and IP56.
Show more information CDH Datasheet
Specifications
| Power Range | PN: 110W - 205W (Steady state or 100% ED) |
| Pulse Load | 40s/120s:. . . . . . . . . . . . . . . . . . . . . . . . . . . . 330W - 615W 10s/120s:. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3kW - 2.4kW 5s/120s: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5kW - 4.9kW 1s/120s: . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0kW - 8.0kW |
| De-rating | Linear: 40°C = PN - 90 °C = 0,75 * PN |
| Environmental | -40 °C - 90 °C |
| Resistance Tolerance | ± 10% (opt: ± 5%) |
| Dielectric Strength | 3500V AC |
| Working Voltage | 600V AC; 850VDC |
| Insulation Resistance | >20M |
| Protection class | IP50 |
| Max surface temperature | 255°C |
| Cooling media | AIR |
| Thermo watch (optional) | 130/160/180/200 °C |
| Connection | Cables |